All
Search
Images
Videos
Shorts
Maps
News
More
Shopping
Flights
Travel
Notebook
Report an inappropriate content
Please select one of the options below.
Not Relevant
Offensive
Adult
Child Sexual Abuse
GSH Fault Finding
Electric Socket
Fault Finding
Rq758n4sai1
Fault Finding
High ZS
Fault Finding
GSH Electrical
UK Electric Domestic Sockets Faulty
Identify Neutral in a Consumer Board
Reverse Polarity
Fault Finding
Faulty Room Thermostat Repair
Test Thermador Eletric Oven Parts
SWA Earthing in Consumer Unit
Echo 330Es
Fault Find
Electrical
Ring Circuit Test
Ring Circuit Spur
Test for
Electrical Polarity
Does Hoover Hi642cbb Have a 13 Amp Plug
Swapping MCB UK
Fault
High Resistance Joint
Fault
Eicr Codes C1 C2 C3
NBR Erec
No Insulation of Busbar in Consumer Unit
What Is
Fault Resistance
High Resistance
Fault
Length
All
Short (less than 5 minutes)
Medium (5-20 minutes)
Long (more than 20 minutes)
Date
All
Past 24 hours
Past week
Past month
Past year
Resolution
All
Lower than 360p
360p or higher
480p or higher
720p or higher
1080p or higher
Source
All
Dailymotion
Vimeo
Metacafe
Hulu
VEVO
Myspace
MTV
CBS
Fox
CNN
MSN
Price
All
Free
Paid
Clear filters
SafeSearch:
Moderate
Strict
Moderate (default)
Off
Filter
GSH Fault Finding
Electric Socket
Fault Finding
Rq758n4sai1
Fault Finding
High ZS
Fault Finding
GSH Electrical
UK Electric Domestic Sockets Faulty
Identify Neutral in a Consumer Board
Reverse Polarity
Fault Finding
Faulty Room Thermostat Repair
Test Thermador Eletric Oven Parts
SWA Earthing in Consumer Unit
Echo 330Es
Fault Find
Electrical
Ring Circuit Test
Ring Circuit Spur
Test for
Electrical Polarity
Does Hoover Hi642cbb Have a 13 Amp Plug
Swapping MCB UK
Fault
High Resistance Joint
Fault
Eicr Codes C1 C2 C3
NBR Erec
No Insulation of Busbar in Consumer Unit
What Is
Fault Resistance
High Resistance
Fault
0:54
Electrical Fault Finding Hack #GSHElectrical #electricalwiring | GSH Electrical Training
12.8K views
6 months ago
Facebook
GSH Electrical Training
0:16
Fault Finding - Low Insulation Resistance Pure water is an insulator but the impurities in it will make it conductive. So this light fitting that has water in it could be one or the reasons why this circuit has a low insulation resistance reading. Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2 and 3. You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”. SparkSafe #GSHElectrical #Electricaltrainingvideos #electric
67.4K views
Jun 19, 2024
Facebook
GSH Electrical Training
6:39
Electrical Fault Finding - Borrowed Neutral and an RCD In this electrical testing and fault finding video UK electrical Matt is trying to track down a missing conductor. Fault finding is an important skill in being a electrician and not all faults are easy to find… Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E. You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”. Matt O'dell #GSHElectr
13.3K views
Jun 9, 2024
Facebook
GSH Electrical Training
4:21
Will it WORK - Using a Clamp Meter for Fault Finding Electrical Fault Finding Earth Leakage Current Detected with the Megger DCM305E Clamp Meter We simulate an earth leakage current (earth fault) with a plug in voltage indicator on a socket circuit (ring final circuit). We use the Megger DCM305E earth leakage clamp meter to find the part of the circuit or appliance causing this earth leakage. We demonstrate how the Megger DCM305E can save you time when looking for fault on electrical circuits. E
21.5K views
Jan 11, 2025
Facebook
GSH Electrical Training
5:08
Ring Circuit Fault Finding 👀 #gshelectrical #electricalwork #electricalwiring | GSH Electrical Training
72.7K views
5 months ago
Facebook
GSH Electrical Training
8:18
UK electrician Matt is fault finding on a ring final circuit. The socket circuit is tripping the RCCB inside of the split load consumer unit. Matts identifies the faulty ring circuit and then uses a logical approach to find the part of the ring that has an earth fault on it. By splitting the ring apart Matt creates a radial socket circuit and then sets about getting as many socket on as possible. It is also interesting to see how this older PVC is staring to break down creating green goo around
212.5K views
May 12, 2024
Facebook
GSH Electrical Training
7:58
Swimming Pool Fault Finding #apprenticeships #electricalapprentice #electricaltrainingvideos #electricalwiringinstallation #electricaltraining #apprentice #apprenticeship #electrician #sparks #GSHElectrical #Electricaltrainingvideos #electricaltesting #ElectricalSafety #BS7671 #electricalinstallation #livingthedream #electricalwork #electrical #apprenticship #sparkylife #electricians #learning #wiring #teaching | GSH Electrical Training
3.1K views
11 months ago
Facebook
GSH Electrical Training
0:27
PEN Fault Risk..? | GSH Electrical Training
4.6K views
10 months ago
Facebook
GSH Electrical Training
6:02
Fault Finding on Kitchen Wiring #apprenticship #electricaltraining #apprenticeships #electricaltesting #electrical #sparks #electricalapprentice #livingthedream #electricalinstallation #electrician #apprenticeship #Electricaltrainingvideos #electricaltrainingvideos #electricalwork #apprentice #GSHElectrical #sparkylife #electricalwiringinstallation #ElectricalSafety #BS7671 #electricians | GSH Electrical Training
16.9K views
1 year ago
Facebook
GSH Electrical Training
6:09
Electrical Testing and Fault Finding - Socket NOT Working for a Dishwasher Marcus and his work experience trainee Eric have been called out to a dishwasher that isn't working. On investigation through both electrical live and dead testing they find out that one of the conductor is broken. This broken conductor is causing the socket outlet for the dishwasher not to work. All the electrical tests are carried out using a Megger MFT tester. Videos are training aids for City and Guilds (C and G) and
28.8K views
Aug 25, 2024
Facebook
GSH Electrical Training
6:38
Panel Wiring and Fault Finding #apprentice #Electricaltrainingvideos #apprenticship #apprenticeship #electrical #ApprenticeshipSuccess #apprenticeships #sparks #electricalwork #electrician #wiring #electricianstools #sparkylife #bs7671 #electricalapprentice #electricaltrainingvideos #ukelectrician #electricalwiring #electricaltraining #electricalinstallation #GSHElectrical #cable #connections #cables #electricaltesting #apprenticeelectrician | GSH Electrical Training
4.7K views
Apr 3, 2025
Facebook
GSH Electrical Training
4:51
Electrical Fault Finding Protective Bonding Conductor to Gas and Water. AM2 and AM2S Assessment Electrical testing and fault finding with Marcus. In this video we explore a fault on the protective bonding conductor that goes to the gas and water (gas or water bond). Using the ohms scale of a Megger MFT tester Marcus explains the fault and how to find it. Update please watch 👇🏻 🔵 How to Test the Protective Bonding Conductor - Testing and Fault Finding Hints and Tips - AM2 & AM2S https://youtu.
11.7K views
Dec 20, 2024
Facebook
GSH Electrical Training
14:13
EICR Fault Finding on Sockets - Reverse Polarity & High Resistance - Ring Final Circuit Testing During an EICR on a ring final circuit (sometimes called a ring main or socket circuit) Matt discovers high resistance on 2 sockets during the figure of eight test and incorrect polarity when live. Matt finds and corrects the fault before testing the circuit the circuit again. Note - this is a snap shot of the work carried out and is designed to raise questions and talking point in Matts classroom les
14.9K views
May 27, 2024
Facebook
GSH Electrical Training
5:37
Electrical Fault Finding Earth Leakage Current Detected with the Megger DCM305E Clamp Meter We simulate an earth leakage current (earth fault) with a plug in voltage indicator on a socket circuit (ring final circuit). We use the Megger DCM305E earth leakage clamp meter to find the part of the circuit or appliance causing this earth leakage. We demonstrate how the Megger DCM305E can save you time when looking for fault on electrical circuits. You can contact Megger instruments for more details vi
5.3K views
Dec 28, 2024
Facebook
GSH Electrical Training
7:47
Testing and Fault Finding - Low Insulation Resistance Fault - Testing at 250 and 500 Volts DC It isn't often that you can carryout the insulation resistance test will all circuit connected because of RCD protection in a consumer unit. In this video Marcus has no RCCB's or RCBO's in the consumer unit (fuse box) so he can test between all line conductor to the neutral bar, all line conductor the the earth bar and between all neutral and earth connections. Marcus shows how using 250 volts DC from h
11.4K views
Jan 19, 2025
Facebook
GSH Electrical Training
7:04
EICR Ring Circuit Fault Finding Issues - Testing an Open Ring Circuit & Low Insulation Resistance On site with electrician Matt testing and fault finding whilst doing an EICR (electrical installation condition report). This video will be used to support classroom teaching at college. Matt highlights issues with the ring final circuit (ring main) open ring test end to end and low insulation resistance test. NOTE - Some further discussion have been left for the classroom lessons. This video gives
14.8K views
May 27, 2024
Facebook
GSH Electrical Training
7:39
Testing and Fault Finding - Low Insulation Resistance Fault - Testing at 250 and 500 Volts DC It isn't often that you can carryout the insulation resistance test will all circuit connected because of RCD protection in a consumer unit. In this video Marcus has no RCCB's or RCBO's in the consumer unit (fuse box) so he can test between all line conductor to the neutral bar, all line conductor the the earth bar and between all neutral and earth connections. Marcus shows how using 250 volts DC from h
11.8K views
Aug 26, 2024
Facebook
GSH Electrical Training
0:58
Total Earth Fault Loop Impedance | GSH Electrical Training
6.1K views
Jan 5, 2025
Facebook
GSH Electrical Training
0:44
EICR - Fault Finding on a Socket Circuit Amazing what you can find when carrying out an EIRC (electrical installation condition report). This ring final circuit (socket circuit) is throwing up some strange readings due to the tightness of conductors. This video has been designed to go on the YouTube shelf as a short video in portrait mode. Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2 and 3. You can follow me day by day on Facebook, Instagram, Twitter and TikT
46.9K views
Dec 6, 2024
Facebook
GSH Electrical Training
0:39
External Earth Fault Loop Impedance Test (Ze) #electricalwork #electricalwiring #gshelectrical | GSH Electrical Training
17.1K views
4 months ago
Facebook
GSH Electrical Training
4:46
Prospective Fault Current PSCC, PEFC, PFC and External Earth Fault Loop Impedance Ze - Live Tests In this video Marcus carries out using the 2 lead high setting on his Megger MFT tester the external earth fault loop impedance (Ze) and prospective fault current tests. These live tests are carried out from inside the consumer unit (fuse board or fuse box) and will confirm the incoming supply has a connection to Earth and that the overcurrent protective devices can withstand the possible high level
8.5K views
Jan 4, 2025
Facebook
GSH Electrical Training
7:20
Fault Finding Testing for Insulation Resistance. Low Reading Insulation Resistance Fault How to test for insulation resistance inside a consumer unit. Marcus is carrying out an electrical inspection and testing when he come across a fault giving him a low reading during the insulation resistance test. These videos will help with AM2, AM2S, AM2E and your apprenticeship end point assessments. The testing and fault finding is carried out with a Megger MFT tester in controlled conditions at Tresham
38.2K views
Dec 10, 2024
Facebook
GSH Electrical Training
7:13
Fault Finding Testing for Insulation Resistance. Low Reading Insulation Resistance Fault How to test for insulation resistance inside a consumer unit. Marcus is carrying out an electrical inspection and testing when he come across a fault giving him a low reading during the insulation resistance test. These videos will help with AM2, AM2S, AM2E and your apprenticeship end point assessments. The testing and fault finding is carried out with a Megger MFT tester in controlled conditions at Tresham
15.2K views
Aug 24, 2024
Facebook
GSH Electrical Training
7:16
EICR Ring Circuit Fault Finding Issues - Testing an Open Ring Circuit & Low Insulation Resistance On site with electrician Matt testing and fault finding whilst doing an EICR (electrical installation condition report). This video will be used to support classroom teaching at college. Matt highlights issues with the ring final circuit (ring main) open ring test end to end and low insulation resistance test. NOTE - Some further discussion have been left for the classroom lessons. This video gives
6.1K views
Jan 21, 2025
Facebook
GSH Electrical Training
7:15
Fault Finding - Storage Heater NOT Working Matt is on site with a storage heater that won't get hot. Matt is fault finding to prove all heater elements are working correctly. It’s important to test the elements correctly as they are connected in parallel and this can lead to false or misleading readings. Matt was working in a controlled environment for the fault finding and at times with the front panel off and live parts exposed. Videos are training aids for City and Guilds (C and G) and EAL co
23.3K views
Nov 5, 2024
Facebook
GSH Electrical Training
12:41
How to Test the Protective Bonding Conductor - Testing and Fault Finding Hints and Tips - AM2 & AM2S This video should help you understand why you must disconnect both end of the protective bonding conductor during your end point assessment AM2, AM2S or AM2E for apprentice electricians when doing the fault finding element of the assessment. Often at college you only have 2 short pieces of copper pipe to simulate the gas and water. In reality the water and gas pipes are connected together by othe
8K views
Dec 18, 2024
Facebook
GSH Electrical Training
12:33
How to Test the Protective Bonding Conductor - Testing and Fault Finding Hints and Tips - AM2 & AM2S This video should help you understand why you must disconnect both end of the protective bonding conductor during your end point assessment AM2, AM2S or AM2E for apprentice electricians when doing the fault finding element of the assessment. Often at college you only have 2 short pieces of copper pipe to simulate the gas and water. In reality the water and gas pipes are connected together by othe
6K views
Aug 28, 2024
Facebook
GSH Electrical Training
5:25
External Earth Fault Loop Impedance Ze Test - How to Remove Parallel Earth Paths - Live Testing In this video me and Marcus show how to carryout an external earth fault loop impedance test on a single phase installation. All stage of this live test are demonstrated as well as the importance of removing parallel earth path created by incoming metal pipework such as the water and gas. This video is designed to help learners with testing and fault finding units in City and Guilds and EAL qualificat
12.1K views
Jun 23, 2024
Facebook
GSH Electrical Training
4:12
Earth Fault Loop Impedance Test - 3 Lead Low or 2 Lead High - Test Explained In this video Marcus explains what happens when we would set our MFT tester to 3 lead low, 2 lead high and even 2 lead low in order to carryout an earth fault loop impedance on a circuit that has RCD protection. So we can carryout a earth fault loop impedance test it is important to select the correct setting on an MFT tester but do you understand why we often select 3 lead low setting when testing for earth fault loop
14.6K views
Jul 21, 2024
Facebook
GSH Electrical Training
8:09
How to Find a Fault on a Ring Final Circuit (Sockets) Help for AM2 & AM2S Testing and Fault Finding EAL Awards City & Guilds SparkSafe How to find fault on a ring final circuit sometime called a ring circuit or ring main. Using a Megger MFT tester Marcus sets about finding an open circuit after carrying out stage one testing end to ends. Marcus show you how to split the ring circuit into 2 radial circuits and then test each leg until you find the faulty socket is identified. Please note there ar
5.7K views
Apr 2, 2024
Facebook
GSH Electrical Training
See more
More like this
Feedback