  1. Wiring a sub panel using 10/2 feeder - DIY Home Improvement …

    Jun 5, 2010 · After initial inspection, I was told I needed to install disconnect, sub panel, and grounding system. I stopped by an electrical supplier to see if I could do this without replacing …

  2. Running a sub panel from 30 amp double pole circuit

    Apr 19, 2020 · Running a sub panel from 30 amp double pole circuit Jump to Latest 10K views 16 replies 5 participants last post by Joeywhat Apr 20, 2020 J

  3. Unusual question about wiring a 30 amp subpanel in a shed

    Oct 14, 2021 · What you propose would work as a 30 amp service, but technically you are not suppose to use NM cable in conduit. I would consider buying aluminum wire and run a 60 amp …

  4. Installing a 30amp breaker in a 100amp sub panel

    Jan 20, 2025 · You can check the wire size from the main panel, match the breaker load and add a 30amp switch if it all checks out. Make sure you have 8 ga wire minimum from the main to …

  5. Can i add a subpanel fed by 10/2 wire? - DIY Home Improvement …

    Apr 10, 2007 · If the service is 200 amps it must be wired with 200 amp wire to a 200 amp breaker or fuse. If the op wants to use 10 wire it would have to run to a 30 amp breaker or fuses …

  6. can I use 12/3 wire for 30 amp subpanel, if I only use a...

    Feb 13, 2022 · I'm trying to run power to a shed, and don't need the full 30 amps (7200) watts of power. I only need about 3000 watts of power. So Can I use a 20 amp breaker, to power a 30 …

  7. Running new wire to sub panel - verifying wire size

    Jan 9, 2023 · 30 Amp breaker requires a 10g wire. A 220 sub-panel requires 10-3 plus ground as the neutral and ground must be separate at the sub.

  8. Air Conditioning Sub Panel - DIY Home Improvement Forum

    Jul 19, 2021 · I have two A/C units outside, each wired to a sub panel, with two 30 amp breakers. One breaker per A/C unit. The sub panel is then wired to my main breaker panel on a 60 amp …

  9. Generator Backfeed to Sub-Panel w/ Interlock...

    Jul 2, 2021 · Here is what my theoretical set-up looks like so far: -7125 starting watt /5700 running watt generator w/ 240v, l14-30 outlet -10/4 generator cable with l14-30 plug and receptacle …

  10. 30amp sub panel for shed?? - DIY Home Improvement Forum

    Nov 9, 2010 · I have a 125A main panel in my home and i want to put power to my shed. well a 30A sub panel be enough? i want a circuit of lights 15A,and a 20A circuit for plugs, and a …